User's Manual Part 3

Screen Service SDT 501 UB-C ARK 1-T Operations
May, 2010 v 1.0 Page 3 - 93
Table 14. Alarms window
Alarm Description and limitations Troubleshooting
Up converter Osc. Unlock PLL of the Up converter board not locked to 120 MHz clock.
Hardware fault
PS Voltage out range (for STDX
20/50/201) or
PS1/PS2 Voltage alarm (for STDX
501)
Voltage out of range. The ranges are:
20V up to 30V for SDTx_ARK1-T SDTX 20/50;
38V up to 44V for SDTx_ARK1-T SDTX 201/501.
Hardware fault
PS Current out of range or (for STDX
20/50/201) or
PS1/PS2 Current alarm (for STDX
501)
The current exceeds the 22 Ampere upper limit of
SDTx_ARK1-T 20W and 50W and the 17 Ampere upper limit
of SDTx_ARK1-T 200W.
Hardware fault
Absolute Power Limiter The output power exceeds the maximum endurable limit.
Hardware fault
Up converter Communication error
Communication errors between ARK1-T main board and
Up-converter board.
Hardware fault
Temperature High Alarm Case temperature over 70°C, the maximum endurable limit.
Temperature Level-3dB
Temperature level goes over the alarm threshold.
The output power is consequently lowered by 3 dBm (always
within the admitted power range).
Temperature High Warning Temperature level goes over the warning threshold.
Check alarm and warning thresholds
Lower the output power to decrease internal temperature