User's Manual Part 3
Screen Service SDT 501 UB-C ARK 1-T Operations
May, 2010 v 1.0 Page 3 - 53
Box
Parameter /
Control
Description Admitted Ranges / Values
MIP MIP cell ID function enabling
Local
Cell Id enable
General Cell Id enabling. Must be enabled to insert Cell Id into output TPS.
• Checked: Enabled
• Not checked: Disabled
MIP MIP cell ID monitoring.
Local Local Cell ID setting.
• Min: 0
• Max: 65,535
Actual
Cell ID
Used Cell ID monitoring.
MIP
Max Delay
[100ns]
MIP max delay function monitoring
Local User Delay
User delay setting.
This value is added to the MIP max delay to calculate the Used delay
• Min: - 8388608
• Max: 8388607
Actual Delay [100ns]
Used delay monitoring.
In SFN this value is calculated adding the MIP max delay, the Local user delay, the MIP Time offset, the
Local time offset and the Device delay
In MFN this value is calculated adding the Local user delay and the Device delay
Note: this value must be greater than the HP and LP network delay
• Min: 0
• Max: 9,999,999