User's Manual Part 3

Screen Service SDT 501 UB-C ARK 1-T Operations
May, 2010 v 1.0 Page 3 - 42
Table 7. Modulation management
Box
Parameter/
Control
Description Admitted Ranges / Values
MFN / SFN MFN/SFN
Selector of Network’s Transmitters Synchronization.
Refer to
Network Synchronization parameter setting
paragraph.
Note: the seamless
input switching work only in SFN and SFN local,
In MFN and MFN MIP
seamless input switching is disabled and the input is forced to input 1
MFN
MFN MIP
SFN
SFN Local
MFN / SFN
Delete Null
Packets
Delete null packets enabling check box.
In SFN and SFN Local transmission modes, this option is disabled by default and can’t be enabled.
In MFN and MFN MIP transmission modes, this option is enabled by default.
Checked: Enabled
Not checked: Disabled
MIP Detection
MIP HP/LP
detected
Detection of MIP packets in HP/LP streams.
Green: Detected
Grey: Not detected