User's Manual Part 3

Screen Service SDT 501 UB-C ARK 1-T Operations
May, 2010 v 1.0 Page 3 - 37
Box
Parameter /
Control
Description Admitted Ranges / Values
HP Input / Input 1
or Input 2
PAT CRC
flag
This flag enables the detection of CRC errors in the PAT to force a switching to the other input.
By disabling this rule the detection of a PAT CRC errors doesn’t force the switching of inputs not raises
any alarm.
Checked: Alarm enabled
Not checked: Alarm not enabled
HP Input / Input 1
or Input 2
MIP CRC
flag
This flag enables the detection of CRC errors in the MIP to force a switching to the other input.
By disabling this rule the detection of a MIP CRC errors doesn’t force the switching of inputs not raises
any alarm.
Checked: Alarm enabled
Not checked: Alarm not enabled
HP Input / Input 1
or Input 2
Sync Error
flag
This flag enables the detection of Sync Error to force a switching to the other input.
By disabling this rule the detection of Sync Error doesn’t force the switching of inputs not raises any
alarm.
Checked: Alarm enabled
Not checked: Alarm not enabled
HP Input / Input 1
or Input 2
Packet Jitter
flag
This flag enables the detection of TS packet out of time reception to force a switching to the other input.
By disabling this rule the detection of a packet jitter error doesn’t force the switching of inputs not raises
any alarm.
Checked: Alarm enabled
Not checked: Alarm not enabled
HP Input / Input 1
or Input 2
Transport
Error flag
This flag enables the detection of Transport Error flag to force a switching to the other input.
By disabling this rule the detection of a Transport Error flag doesn’t force the switching of inputs not
raises any alarm.
Checked: Alarm enabled
Not checked: Alarm not enabled