User's Manual Part 3

Screen Service SDT 501 UB-C ARK 1-T Operations
May, 2010 v 1.0 Page 3 - 36
Box
Parameter /
Control
Description Admitted Ranges / Values
HP Input Switch State
This monitor shows the current device switch state. When both the two inputs are available, the input
seamless switching is possible; else, if only one input is available, then the switching is no more
available. If some error occurs on both inputs, device can’t switch and it can’t use any input.
Stop
Input 1 only
Input 2 only
Seamless
Wait
HP Input / Input 1
or Input 2
Network
Delay
[100 ns]
This monitor shows the Network Delay, measured analyzing MIP contained in the input. This delay is
expressed in units of 100 ns.
Min: 0
Max: 9999999
HP Input / Input 1
or Input 2
PMT CRC
flag
This check isn’t implemented in the actual version.
Checked: Alarm enabled
Not checked: Alarm not enabled