Alarm Description and limitations Troubleshooting
DVB-T 1PPS Lock
1PPS is not lock to the selected frequency reference. This
alarm’s RF OFF mask should always be enabled.
Alarm raising limitations:
The monitoring of this alarm is disabled when external 1 PPS
is not used (Heterodyne repeater modes) or when internal 1
PPS is selected (clock ref. set to internal) or when GPS clock
reference is selected and one of the GPS alarms (GPS
signal lock, GPS comm. alarm) is raised.
•
If the frequency reference is Internal: internal PLL fault
•
If the frequency reference is External:
o Internal PLL fault
o Lack of external 1PPS
o Hardware fault
•
If the frequency reference is Internal:
o Check GPS alarms
o Internal PLL fault
o Hardware fault
DVB-T PPS Phase
1PPS is not lock to a common reference of the network. This
alarm’s RF OFF mask should always be enabled.
Alarm raising limitations:
The monitoring of this alarm is enabled only when the device
has SFN modulation enabled.
•
Check 1PPS
•
Hardware fault