Alarm Description and limitations Troubleshooting
DVB-T 1PPS Lock
1PPS is not lock to the selected frequency reference. This
alarm’s RF OFF mask should always be enabled.
Alarm raising limitations:
The monitoring of this alarm is disabled when external 1 PPS
is not used (Heterodyne repeater modes) or when internal 1
PPS is selected (clock ref. set to internal) or when GPS clock
reference is selected and one of the GPS alarms (GPS
signal lock, GPS comm. alarm) is raised.
If the frequency reference is Internal: internal PLL fault
If the frequency reference is External:
o Internal PLL fault
o Lack of external 1PPS
o Hardware fault
If the frequency reference is Internal:
o Check GPS alarms
o Internal PLL fault
o Hardware fault
DVB-T PPS Phase
1PPS is not lock to a common reference of the network. This
alarm’s RF OFF mask should always be enabled.
Alarm raising limitations:
The monitoring of this alarm is enabled only when the device
has SFN modulation enabled.
Check 1PPS
Hardware fault