User`s manual

Chapter 7 - SETUP PART 5: Learning the LCD and User Interface Controls
34
T-Jet Blazer Series User’s Manual
Pressing the DOWN button lowers the Platen (Print Bed) giving more clearance.
The distance of the platen (with the substrate loaded) needs to be set to a minimum of 3mm to a
maximum of 5mm in relation to the Printer Assembly. This distance will depend on what distance is used
in performing your Print Head Alignment. Learn more in Chapter 8 - SETUP PART 6 - Initialization
Utilities.
System Printer Control Utility (SPCU) Screen
The SPCU has been discontinued. Your printer may or may not
have this screen available, but if so, the functions on this screen
should be utilized from the LCD Display Control Panel rather than
here.
To Reset a job or clear all jobs on the LCD Display Controls, press
and hold the Pause Button for 3 seconds.
To Pause a job on t he LCD Display Controls, press the Pause
Button.
The Alarm Select Screen
You may hear a tone when performing certain actions,
such as sending a print command. You will also notice
blinking of the green lights before and after printing. The
Alarm Select Screen allows you to control whether or
not you will hear or see these various audible and visual
alarms.
Press any or both of the touch screen switches to turn the
alarms either on or off.
NOTE: To adjust these settings ensure the virtual dial on
the Mode Select Screen is set to Manual.
IMPORTANT POINT
Anytime you choose the Manual mode from the Mode Select Screen, you must
remember to return to that screen and switch the virtual dial to Auto to enable
printing.