User`s manual

initiate printing.
Pressing and holding the Index button for 2
seconds will move the Printer Assembly to the
front of the Platen. This is the maintenance
position from which you would perform Nozzle
Checks, Head Alignments, etc.
Pressing and holding the Nest button for 2
seconds will move the Printer Assembly forward
or backward and align it with the front sensor.
No printing or maintenance functions should
be performed from this position. This is ONLY to
check the functionality of the sensor.
Byusingthe“Jog”options,youcancontrolnitemovementsofthePrinter
Assembly.
Pressing the FOR button, moves the printer incrementally toward the front •
of the Platen.
Pressing the REV button, moves the printer incrementally toward the end •
of the Platen.
The Platen to Head Clearance Adjust (PHCA) Screen
The PCHA screen is used to set the proper
clearance (3mm) between the Platen and
the Print Head.
Pressing the UP button raises the Platen.•
Pressing the DOWN button lowers the •
Platen
System Printer Control Utility (SPCU) Screen
The SPCU screen can be utilized instead of the menu on the printer’s LCD control
panelinspecicinstances.
19
Chapter 3- Interacting with Your Printer