User`s manual
T-Jet Blazer Series User’s Manual
Version 5.0 Revised September, 2008
34
Pressing the DOWN button lowers the Platen (Print Bed) giving more clearance. •
The distance of the platen (with the substate loaded) needs to be set to a minimum of 3mm to a maximum
of 5mm in relation to the Printer Assembly. This distance will depend on what distance is used in
performing your Print Head Alignment. Learn more in Chapter 8 - Initialization Utilities.
System Printer Control Utility (SPCU) Screen
The SPCU has been discontinued. Your printer may or may not
have this screen available, but if so, the functions on this screen
should be utilized from the LCD Display Control Panel rather than
here.
To Reset a job or clear all jobs on the LCD Display Controls, press
and hold the Pause Button for 3 seconds.
To Pause a job on t he LCD Display Controls, press the Pause
Button.
The Alarm Select Screen
You may hear a tone when perfoming certain actions, such
as sending a print command. You will also notice blinking
of the green lights before and after printing. The Alarm
Select Screen allows you to control whether or not you
will hear or see these various audible and visual alarms.
Press any or both of the touch screen switches to turn the
alarms either on or off.
NOTE: To adjust these settings ensure the virtual dial on
the Mode Select Screen is set to Manual.
IMPORTANT POINT
Anytime you choose the Manual mode from the Mode Select Screen, you must
remember to return to that screen and switch the virtual dial to Auto to enable
printing.