User`s manual
dust. This includes, but is not limited to, the Pretreatment used when printing with
Whiteink.Ifthisisunavoidable,theprintershouldbeisolated,eitherbyefcient
extraction of mist and fumes or by partitioning. Heavy dust and ink mist can
cause reliability problems with the printer.
It MUST not be placed in an open warehouse that is hot, dry, dusty or has
excessiveoorvibration.Ifyoumustplaceitinanopenroomthatisnot
environmentally controlled, you can build a temporary enclosure out of plastic
and building materials. This enclosure must comply with local building codes.
Exceedingtheenvironmentalspecicationscancausetheprintingof
substandardimagesduetomisringofPrintNozzlesandinkprematurelydrying
on the surface of the Print Head. This misuse may void the warranty.
Exhaust Ventilation Requirements
Exhaust ventilation and air-conditioning of the Fast T-Jet Blazer Express printer is
REQUIREDforpropermachinefunction.Thismachinedoesnotproduceodors
and the ink is non-toxic, however adequate ventilation is required for the use of
Pretreatment. When curing shirts, chemicals released from the shirt are non-toxic
but may be eye irritants.
Room Conditions
Temperature- 68 to 85°F (20 to 29°C)
Relative Humidity- 40% to 80% (non-condensing)
Platform- Strong enough to support equipment weighing up
200 lbs. Flat and level (allowable variation: 1/8” in. 40-in.
run (3 mm in 1000 mm run). Minimize vibration from
surrounding equipment
Ambientlightlevel- Generalofceenvironment(700–1000lux)
Type- White,indirectuorescentlight
Room- At least 5 air changes per hour with a minimum of 20%
fresh air coming in through air return is recommended.
This is more for operator comfort.
Heat Load- 4000 watts
AirQuality- Cleananddustfreewithnoheavyair-owblowing
across the machine.
Room Access- 36 inch (92 cm) minimum doorway
Electrical Requirements
A dedicated circuit for your printer and PC computer is strongly recommended.
This circuit should be 110V minimum to 240V maximum, 50/60 Hz, 15A load, single
116
Fast T-Jet Blazer Express User’s Manual