4.5 ADD-ON TO ELECTRIC CONTROL KIT “E”(Fig S202-8, Fig S202-9)
Control kit “E” is required for ADD-ON to Electric installation of the KERR SCOTTY SS
Wood Furnace model DB-202A.
Kit “E” consists of the following:
1. L4064R1027 11” Primary Fan Limit Control (Wood Furnace) complete with
standoff bracket. Fan “ON” 140° F, Hi Limit 280° F. Check JUMPER
REMOVED. See “Note” below.
2. M847A1031 Draft Damper Motor complete with chain and S hook. Lifts damper
in response to wood thermostat’s call for heat. Be sure that damper gate is fully
closed when damper motor is not powered. Connect chain to first or second hole
up in wheel. Leave bottom chain link open for emergency disconnect see
description below.
3. T822D1826 thermostat. In ADD-ON installations, mount adjacent to electric
furnace thermostat and label “wood”
Note: anticipator setting 0.32 amps. See description below.
4. White-Rodgers 8A05A-4 Switching Relay. Prevents wood furnace and electric
furnace from firing at the same time.
5. Damper Control stand off mounting plate c/w decal.
6. Cable stand off brackets and cable clips
7. 12 ½” x #8 sheet metal screws
8. Wiring Harness c/w 4 x 4 box, 2 flex conduit, wirenuts, antishorts and squeeze
connectors
9. 3 1-1/2” x #10 sheet metal screws for fastening fan control to mounting bracket
IMPORTANT follow carefully the electrical schematic (decal on wood furnace cabinet
or Fig, S202-8 or 9). The electric power for the wood furnace must be supplied from the
fused single branch circuit inside the electric furnace cabinet. A ground wire is
necessary between the wood and oil furnaces.
NOTE Remove Fan Limit Control jumper connection indicated in Figure S202-8.