Manual
Table Of Contents
What to do before calling for service
Low capacity
• Check for restricted drain or standing water
in the bin
• Clean the air cooled condenser fins
• Clean the ice making system
No ice
• Check on-off switch
• Check electrical breaker
• If the Check Water light is flashing Red,
check water supply. The control system
checks for water every 20 minutes. When the
water supply is restored, the machine will
automatically restart ice making.
• If the all the lights are flashing, the auger
motor has overloaded or is not operating.
Call for service.*
Time to Clean light is on
• Clean the ice making system.
* Technical note:
One blink and repeat indicates an overload,
Two blinks and repeat indicates an open motor.
Reset by pressing the on/off button.
July 2018
Page 16
SCN60
User's Manual
Erratic drain pump operation (pump models only)
• Clean and sanitize bin. If the problem
continues contact a local service provider
Bin and drain system
Over time biofilm can grow inside the drain system
which can affect the ability for the drain sy
stem to
evacuate the drain water. On the pump models this
can also drive a erratic pump operation. Including
the pump cycling rapidly or running all the time.
Biofilm and pump cycling issues will eventually lead
to low production and standing water in the bin. To
ensure that this does not become an issue frequent
bin sanitizing may be required.
The ice storage bin should be sanitize occasionally.
It is usually convenient to sanitize the bin after the
ice making system has been cleaned, and the
storage bin is empty. A sanitizing solution can be
made of 1 ounce of household bleach and two
gallons of hot (95oF. –115oF.) water. Use a clean
cloth and wipe the interior of the ice storage bin
with the sanitizing solution, pour some of the
solution down the drain. Allow to air dry.
What to do before calling for service