Service manual
To Remove and Repair the Gearmotor
Assembly:
(Assuming that the procedures through
removal of the water seal have been
performed.)
1. Remove the electrical wires from the gear
drive motor.
2. Unscrew the 4 cap screws holding the
gearmotor to the base of the machine.
3. Remove the gearmotor from the ice maker.
Bench test the gearmotor, check for oil leaks,
noise, and amp draw.
To Remove the Condenser Fan Motor
Assembly
1. Remove top panel.
2. Unplug the two fan motor wire leads from
the fan motors.
3. Remove the two hex head bolts from the top
end of the fan motor assembly.
4. Lift up and pull out the fan motor assembly.
5. Repair as needed.
6. To reassemble: Place the fan motor
assembly lower flange holes over the two allen
head cap screws in the base, and reinstall the
hex head bolts at the top of the assembly.
Plug the fan motors back in, and replace the
top panel.
REMOVAL AND REPLACEMENT
Electrical shock
hazard.
Electrical shock can
cause personal injury.
Disconnect power
before beginning to
service components.
NM952
August 1993
Page 28