Service manual
SPECIFICATIONS
ice making capacity
ELECTRONIC MODULAR SUPERFLAKER
MODEL MF 56
NOTE. The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature and age of the machine.
To keep your SCOTSMAN FLAKER at peak performance levels, periodic maintenance checks
must be carried out as indicated on maintenance section of this manual.
Page 8
Important operating requirements:
MIN MAX
• Air temperature 10°C (50°F) 40°C (100°F)
• Water temperature 5°C (40°F) 35°C (90°F)
• Water pressure 1 bar (14 psi) 5 bars (70 psi)
• Electr. voltage
• variations from voltage
• rating specified
• on nameplate -10% +10%
700
650
600
550
500
450
400
350
300
Kg.
32 °C27 21 15 10
°C
10
21
o
o
32
38
600
575
550
525
500
475
450
425
400
Kg.
°C
°C
10
21
32
38
o
o
AIR COOLED MODELS
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.
WATER COOLED MODELS
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.
32 27 21 15 10