Service manual
December 2009
Page 29
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Heat Load, Charge and Condenser GPM
Heat Load - Average heat load for air conditioning unit
sizing
Water Cooled Water Use - Condenser Only
Refrigerant Charge
Model BTUH
N0422, F0522A 5000
N0622, F0822A 7100
N0922, F1222A 10500
N01322, F1522A 16000
Model GPM @ Supply Water Temp
N0422, F0522W .14 @ 50
o
F water .23 @ 70
o
F water
N0622, F0822W .21 @ 50
o
F water .40 @ 70
o
F water
N0922, F1222W .68 @ 50
o
F water .76 @ 70
o
F water
N01322, F1522W .32 @ 50
o
F water .59 @ 70
o
F water
Model R-404A (oz)
N0422A, F0522A 14
N0422W, F0522W 11
N0622A, F0822A 14
N0622W, F0822W 11
N0622R, F0822R 192
N0922A, F1222A 18
N0922W, F1222W 20
N0922R, F1222R 192
N1322A, F1522A 34
N1322W, F1522W 18
N1322R, F1522R 192