Service manual

Technical Information
Pressure Switches
Compressor Amp Draw
Auger Drive Motor Amps
September 2009
Page 28
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Cut IN (PSIG) Cut OUT (PSIG)
High pressure switch, AC, WC, RC 350 450
Low pressure switch, AC or WC 30 15
Low pressure pump down (remote) 30 15
Model Voltage Brand Amps
N0422, F0522 115 Tecumseh 5.9-6.1
N0622, F0822 115 Tecumseh 5.9-6.1
N0622, F0822 230 Tecumseh
N0922, F1222 230 single phase Tecumseh 4.7-5.1
N0922, F1222 230 three phase Copeland 3.9-4.1
N1322, F1522 230 single phase Copeland 6.9-7.2
Model Ice Machine Voltage Auger Motor Amps Control Cut Out Amps
N0422 or F0522 115 3.4 - 4 6
N0622 or F0822 115 3.4 - 4 6
N0622 or F0822 230 1.1 - 2 3
N0922 or F1222 230 single phase 1.1 - 2 3
N0922 or F1222 230 three phase 1.1 - 2 3
N1322 or F1522 230 single phase 1.1 - 2 3
N1322 or F1522 230 three phase 1.1 - 2 3
Components
Motor: 115 volt or 230 volt versions. 1/4 HP split phase.
Gear Case: Aluminum die cast, service part has no bearings
First gear: Phenolic for noise suppression. Pressed on ball bearing.
Second gear: Steel. Pressed on ball bearing.
Output gear: Steel, pressed shaft and bearings. Supplied with gear case cover.
Output shaft. Provides engagement to auger, uses centering pin for auger alignment. Supplied
with gear case cover.
Input or motor shaft seal. Labyrinth type with o-ring to seal rotor bearing to cover.
Output shaft seal. Lip seal, supplied with gear case cover.