Service manual
AutoAlert and Display Code
The controller uses indicator lights to provide the
user with information on Power, Status, Water or
Time to Clean. These are known as the AutoAlert
panel.
Additionally a 7 segment display is under the front
panel. It shows operational status or problem
codes.
The Power light is on Green anytime the machine
is supplied with electrical power.
The Status light is on Green when the machine has
been switched to the ice making mode. It will also
blink green if the unit has been equipped with an
optional Smart-Board AND the Smart-Board has
detected potential malfunction.
The Water light will blink Red if the water sensor
does not detect water.
The De-Scale / Sanitize light will glow Yellow when
the time to clean timer has reached its set time
since the last cleaning. It also blinks during the first
part of the cleaning mode.
September 2009
Page 16
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Code Description
.... ....FreezeMode
flashes . . Freeze Mode is Pending
.... ....BinisFull
.... ....Clean Cycle
.... ....BoardLocked
.... ....TestMode
.... ....Off
.... ....SelfTestFailed
flashes. . No ice sensed - Retrying
..... ....Noicesensed-ShutDown
flashes . Auger motor high load - Retrying
.... ....Auger motor high load - Shut Down
.... ....Nowaterinreservoir
.... ....Refrigeration pressure too high / low
- Unit Remotely
Locked Out - Contact Leasing Company
F
F
b
C
L
d
O
E
1
1
2
2
3
4
All 4 Upper Lights Flashing