Spec Sheet
ECC Series Remote
Condensing Unit
1-800-SCOTSMAN Fax: 847-913-9844 customer.relations@scotsman-ice.comwww.scotsman-ice.com
101 Corporate Woods Parkway, Vernon Hills, IL 60061
SIS-SS-ECC CHN 02-18© 2018 Scotsman Ice Systems.
Specifications
Model Overall length
(in) (in)Number
Mounting
Hole Spacing
Breaker (amps)
Max. Fuse Size
or HACR Circuit
Wires
Circuit
Ampacity
Min. Circuit
Weight
Shipping
lb/kg
Depth
(in)
Height Basic Electrical
(in)
Contains
Headmaster?
Shipping Carton
L x W x HCircuits
ECC0800-3 42” x 33.5” x 45.5”39.09 27.00 32.06 39.75 208-230/60/3 15 3 10.6 Yes 319/145
ECC0800-6 42” x 33.5” x 45.5”39.09 27.00 32.06 39.75 230/50/1 20 2 16.8 Yes 319/145
ECC1200-32 42” x 33.5” x 45.5”39.09 27.00 32.06 39.75 208-230/60/1 30 2 17.7 Yes 310/141
ECC1410-32 42” x 33.5” x 45.5”39.09 27.00 32.06 39.75 208-230/60/1 30 2 15.8 Yes 332/151
ECC1410-3 42” x 33.5” x 45.5”39.09 27.00 32.06 39.75 208-230/60/3 20 3 11.6 Yes 332/151
ECC1800-3 42” x 33.5” x 45.5”39.09 27.00 32.06 39.75 208-230/60/3 30 3 19 Yes 310/141
ECC Series Remote Condensing Unit
Air Cooled Remote Condensing Unit
AIR IN
AIR IN
AIR OUT
Operating Requirements: Electrical Voltage Min. -10% Max. +10%
Accessories
3BRTE20-EH - 20ft insulated line set. Refrigerant and brazing required.
3BRTE35-EH - 35ft insulated line set. Refrigerant and brazing required.
3BRTE50-EH - 50ft insulated line set. Refrigerant and brazing required.
3BRTE75-EH - 75ft insulated line set. Refrigerant and brazing required.
KSLT075 - Suction line trap for locating ice maker more than 20ft below condenser unit.
Note: These units are designed to be controlled by the ice machines they are connected to.