REPAIR
Cube Size Control
The cube size control controls the timer during the
freeze cycle. If the timer will not start, the cube size
control may be the problem. Removal of the cube
size control requires removal of the ice storage bin.
1. Unplug or disconnect the electrical power to the
ice machine.
2. Remove the kickplate.
3. Go thru the steps to remove the ice storage bin.
4. Remove screws holding cube size control body
to control box.
5. Remove wires connected to the cube size
control. Note: New control wiring will be different,
follow instructions supplied with the the control.
·
Prior to D series: Black to 3, Red to 6, Blue to 4.
·
D and higher: Yellow to 3, Blue to 6.
6. Carefully pull cube size control and attached
capillary tube from the control box, and follow the
capillary tube to the top of the evaporator.
7. The end of the cube size control is inserted into
a socket attached to the evaporator.
8. Remove the cube size control from the socket
and from the ice machine.
9. Reverse the above steps to replace.
10. Adjust the cube size control per the adjustment
sequence on page 16.
Bin Thermostat
The bin thermostat is the automatic on-off control
for the ice machine.
1. Unplug or disconnect the electrical power to the
ice machine.
2. Pull the machine out from its installed location.
3. Remove the back panel.
4. Remove the kickplate.
5. Remove the control knob
6.. Remove the control box cover.
7. Remove the screws holding the bin thermostat
to the control box.
8. Remove the wires attached to the bin
thermostat.
9. Pull the bin thermostat and capillary tube from
the control box, trace the capillary tube to the bin
level control tube and remove the capillary tube
from the tube. Remove the bin thermostat from the
ice machine.
10. Reverse the above steps to replace.
DCE33
July 2014
Page 25
Electrical Shock Hazard
Disconnect Electrical
Power Before Beginning
Removal of Parts
Socket
Pig Tail
CUBE SIZE CONTROL
REPLACEMENT
Capillary Tube
Bin Thermostat