REPAIR
Timer - All except DCE33A-1BD or
DCE33PA-1BD
The timer may need to be replaced if it does not
turn, or if it turns and then stops (except at the end
of the harvest cycle - the timer will ALWAYS stop at
the end of the harvest cycle), or if the microswitch
mounted to it does not switch the machine from the
freeze to the harvest and back again.
Caution: The timer is controlled by the cube size
control, and will not turn if the cube size control
does not work.
1. Unplug or disconnect the electrical power to the
ice machine.
2. Remove the kickplate.
3. Remove the control box cover.
4. Remove the screws holding the timer to the
control box.
5. Disconnect the wires at the timer microswitch.
6. Disconnect the wires from the timer motor at the
terminal board.
7. Remove the timer from the ice machine.
8. Reverse the above steps to replace.
Harvest Timer - DCE33A-1BD or DCE33PA-1BD
1. Disconnect electrical power.
2. Remove service panel.
3. Remove screw in center of timer, pull out and
disconnect wires.
4. Reverse steps to reassemble.
DCE33
September 2011
Page 24
Electrical Shock Hazard
Disconnect Electrical
Power Before Beginning
Removal of Parts
Timer