HARVEST TIME ADJUSTMENT, models DCE33A-1BD or DCE33PA-1BD
The harvest time can be adjusted so that all the ice
is released during the harvest period, with a few
seconds extra for a safety margin. The adjustment
range is between 2 to 5 minutes.
There is an adjustment screw on the surface of the
electronic timer. Rotate the screw CCW to reduce
harvest time, and CW to increase it. It should be
set to match the machine's performance. If the
machine takes 2 and a half minutes to release the
ice, the harvest time should be set to about 3
minutes.