Bin’s ice level.
When the ice machine shuts off the ice level in the
bin should be even with the metal tube inside the
bin. If the ice in the bin is too high or low, turn the
ice machine control knob to adjust the bin
thermostat.
1. To lower the ice level, turn the knob
counterclockwise. Usually a 1/8 turn will be
enough.
2. To increase the ice level, turn the knob
clockwise. Usually a 1/8 turn will be enough.
Timer - up to DCE33A-1BD or
DCE33PA-1BD
The amount of harvest time may be adjusted. It is
preset from the factory at about 3 minutes, which
should be adequate to release all cubes and fill the
reservoir. If the timer needs to be adjusted:
1. Unplug or disconnect the electrical power.
2. Remove the kickplate.
3. Remove the control box cover.
4. Locate the timer, and loosen the set screw that
holds the two halves of the timer cam together.
5. Rotate one half of the cam to open or close the
lower portion of the cam. More of an opening
equals more harvest time and less of an opening
means less harvest time.
6. Tighten the set-screw.
7. Replace the control box cover and kickplate.
8. Reconnect the electrical power.
DCE33
September 2011
Page 19
Timer Set Screw
ADJUSTMENT OF THE TIMER
Electrical Shock Hazard
Disconnect Electrical
Power Before Beginning
Removal of Parts
ADJUSTMENTS