SER VICE DI AG NO SIS
DCE33 User's Manual
J
uly 2018
Page 17
PROBLEM POSSIBLE CAUSE PROBABLE CORRECTION
No ice falling in bin, but machine
operates
Ice may be stuck in the evaporator
and the unit is “frozen up”.
Check water supply - filter may be
restricted
Check inlet water valve - screen
may be restricted, or valve does
not operate.
Hot gas valve may not operate -
check and repair/replace.
Harvest time set too short - timer
needs adjustment.
Too much heat load. Inlet water valve leaks thru, needs
to be replaced.
No water spray Water pump does not work,
replace it.
Water leak from reservoir, locate
and repair.
Cube size control will not close See “Too much heat load” or “not
enough refrigerant”
Control defective - must be
replaced.
No airflow Fan motor not turning, needs to
be replaced.
Fan blade broken, needs to be
replaced.
Condenser completely blocked
up, needs cleaning.
Standing water in the bin Drain line restriction or drain pump
maintenance required
Remove restriction or contact
service provider to check drain
pump operation