Installation Sheet

March 2010
Page 7
Notes for the Installer
Sealing to oor: In some cases the base of
the ice machine must be sealed to the oor to
meet local code. Food grade silastic sealant
such as Scotsman part number 19-0529-01 is
recommended.
Place the machine in the intended location. Turn
the leg levelers in until the bottom of the unit is as
close to the oor as possible. Be sure the unit is
level and all four levelers are in contact with the
oor.
Place a bead of the sealant between the oor and
the outside edge of the cabinet. The bead must ll
the space between the cabinet bottom edges and
the oor.
Installations on a slab: Use a pump model and
pump the water to the point of drainage. Pump
models will pump 1 story (10 feet) high.
Installations over a crawl space or basement:
Either gravity drain or pump model units may
be used, if there is not enough room behind the
machine for a drain/waste receptacle, the drain will
have to be below the oor.
Note: When installed in a corner, the door swing
may be limited due to handle contact with the wall
or cabinet face.