Service manual
Electrical
The machine is supplied with a power cord.
This is a cord-connected unit, and must be on a
separate power supply. Check the dataplate for the
voltage, ampacity and maximum fuse size and per
the dataplate use fuses or HACR circuit breakers.
Follow All Local Codes - This Unit Must Be
Grounded. Do not use extension cords and do not
disable or by-pass ground prong on electrical plug.
Typical Ice Making Cycle Times (minutes).
Listed times are for clean machines in proper
installations. Cycle length at startup will be longer
until the system stabilizes.
Model
70
o
F air /
50
o
F. water
90
o
F. air /
70
o
F. water
CU1526A 22-25 36-29
CU1526W 21-24 28-31
CU2026A 15-18 25-28
CU2026W 15-18 20-23
CU3030A 12-15 19-22
CU3030W 10-13 15-18
May 2008
Page 9
CU1526, CU2026, CU3030
Service Manual