Service manual

Wiring Diagram, CU1526 and CU2026 50 Hz
May 2008
Page 47
CU1526, CU2026, CU3030
Service Manual
USE COPPER CONDUCTORS ONLY
THIS UNIT MUST
BE GROUNDED.
CAUTION:
MORE THAN ONE DISCONNECT MEANS MAY BE
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
17-3196-01
ON/OFF
SWITCH
FUSE
(3A)
O
ON/OFF
SWITCH
O
FUSE (3A)
GN
*
*
TRANSFORMER
5
4
2
1
9
7
6 10
LINE
LOAD
12V
230V
BK
BK
W
BN/W
W
Y
W
FAN CYCLING
PRESSURE
SWITCH
(A/C ONLY)
HARVEST ASSIST
SOLENOID 1
ICE
THICKNESS
PROBE
CURTAIN
SWITCH 2
(2 PLATE UNITS ONLY)
CURTAIN
SWITCH 1
CURTAIN SWITCH
J6
1234
CAUTION: PTCR WILL BE HOT.
COMPRESSOR MAY NOT START IF
PTCR IS NOT ALLOWED TO COOL
MOT
FAN
(WHEN 2ND
FAN IS PRESENT)
W/Y
(AC ONLY)
(WATER COOLED ONLY )
(AIR COOLED ONLY)
FAN
MOTOR
Y
HIGH
PRESSURE
CONTROL
(WC ONLY )
L1 T1
L2
T2
CONTACTOR
MOT
PUMP
SOLENOID
SOLENOID
HOT GAS
WATER
RUN
CAP
PTCR
POWER SUPPLY
SEE NAMEPLATE FOR
PROPER VOLTAGE REQUIREMENTS
AND MAXIMUM FUSE SIZE
L1
L2
LINE
12V
TRANSFORMER
HOT GAS VALVE
WATER VALVE
CONTACTOR
COIL
COMPRESSOR
RUN
CAP.
WATER
PUMP
PTCR
CONTACTOR T1
WATER
LEVEL
SENSOR
SUMP
TEMP.
DISCHARGE
TEMP.
ELECTRONIC CONTROL
BN
W
BU
W
BK
W
R/W
V
BN/W
BK
W
ELECTRONIC
CONTROL
BK
R
W/R
W/R
W
DUMP
VALVE
BK
DUMP
VALVE
HIGH PRESSURE
CONTROL
MOT
FAN
W
BN
FAN
MOTOR
(WHEN APPLICABLE)
(AC ONLY)
4321
J1
3
2
1
J9
7654321
J2
2
1
J8
2
1
J7
R
8
FAN CYCLING PRESSURE
CONTROL SWITCH
(AIR COOLED ONLY)
BN
DISCHARGE
TEMP.
SENSOR
SUMP TEMP.
SENSOR
WATER
LEVEL
SENSOR
W
BK
R
EARTH GROUND
J10
HARV ASSIST
SOLENOID
ICE
THICKNESS
PROBE
BK
W
GN/Y
GN/Y
.33
uF
Y
C
S
R
START WINDING
RUN WINDING
BK
W
R
BK
EXTERNAL
PROTECTOR
COMPRESSOR