Service manual

Cuber System Information
Overall System Type:
Refrigeration: Mechanical, either air cooled or water cooled
Water System: Inlet water float valve fills reservoir continuously. Purge solenoid valve opens to
discharge some reservoir water once per cycle.
Control System: Electronic
Harvest cycle sensor: Conductivity probe
Water full/empty sensor: Conductivity probe
Bin Control: Curtain Switch
Ice type: Unified
Harvest system: Hot gas defrost with mechanical assist
Electrical Components:
Compressor
Contactor
Water Pump
Purge or purge Valve
Fan Motor(s)
Fan motor pressure control
High pressure cut out
Harvest Assist Solenoid
Hot Gas Valve
Controller
Transformer – 12v AC for the controller only
Water Sensor
Ice Thickness Sensor
Curtain Switch
May 2008
Page 13
CU1526, CU2026, CU3030
Service Manual