Specification Sheet
CU1526 / CU2026 - 150lb / 200lb
Self-Contained Ice Machine
1-800-SCOTSMAN Fax: 847-913-9844 customer.relations@scotsman-ice.comwww.scotsman-ice.com
101 Corporate Woods Parkway, Vernon Hills, IL 60061
Accessories
Kit 6 inch leg SSKLP8S
Kit Prodigy undercounter floor mount 26 inch for CU1526 - CU2026 
(add .5” to height)
KPUFM26
Model Number Description
Scotsman recommends all ice machines have water filtration. See Scotsman water filter specification sheet for details.
All Models
Dimensions (W x D x H):
Unit:
26” x 27 3/8” x 33”*
(66.0 x 69.5 x 83.8 cm)
* Add 6” for legs.
29” x 30” x 39”
(73.7 x 76.2 x 99.1 cm)
30” x 32” x 40”
(76.2 x 81.3 x 101.6 cm)
Shipping Carton:
Refrigerant:
Shipping Weight: CU1526: 150lb / 68kg
CU2026: 175lb / 80kg
CU1526:
CU2026:
BTUs per hour: CU1526: 3,100
CU2026: 3,900
CU1526: R-404A
CU2026: R-134A
SIS-SS-PRD-CU26 02-18© 2018 Scotsman Ice Systems.
CU1526 / CU2026 - 150lb / 200lb Self-Contained Ice Machine
Prodigy Undercounter Cuber with Storage
®
CU1526 / CU2026
Installation Note:  Allow 6” at back for utility connections
5.48
13.9
38.82
98.6
22.12
56.2
Air In
Air Out
1/2” FPT
Condenser
Drain
WC Units Only
3/8” Flare
Machine 
Water Inlet
3/8” FPT
Condenser
Inlet
WC Units Only
3/4” FPT
Machine
Drain
Electrical
Entrance
[69.5]
 27.35
[15.2]
 6.00
[75.3]
29.65
CU1526/CU2026 front view
Specifications
Model Number*
Cube Size: medium or small
Condenser
Unit
Basic Electrical
Volts/Hz/Phase
Max. Fuse Size
or HACR Circuit 
Breaker (amps)
Circuit
Wires
Min. Circuit
Ampacity
Energy Consumption
kWh/100 lb (45.4 kg)
90˚F(32˚C)/70˚F(21˚C)
sm.med.
CU1526MA-1
CU1526MW-1
CU1526SA-1
Air
Water
Air
Water
115/60/1
115/60/1
115/60/1
115/60/1
15
15
15
15
2
2
2
2
Cord
Cord
Cord
Cord
9.49
6.58
9.49
6.58
18.0/68.2
19.0/72.0
18.0/68.2
19.0/72.0
-
135/511
CU2026MA-1 Air 115/60/1 15 2 Cord 7.23 21.0/79.6 -
-
135/511
CU1526SW-1
Air 115/60/1 15 2 Cord 7.23 21.0/79.6 -
CU2026SA-1
Water
Storage
lb/kg
80/36
80/36
80/36
80/36
80/36
CU2026MA-32 Air 208-230/60/1 15 2 Cord 7.23 21.0/79.6 -80/36
80/36
80/36 115/60/1 15 2 Cord 5.28 18.0/68.2 105/398
CU2026SW-1
Water 80/36 208-230/60/1 15 2 Cord 5.28 18.0/68.2 105/398
CU2026SW-32
90˚F(32˚C)/70˚F(21˚C)
Water Usage 
Gallons/100 lb (liters/45.4 kg)
Potable Condenser
Specifications and design are subject to change without notice.
Operating Requirements
Minimum
Air Temperatures
Water Temperatures
Water Pressures
Electrical Voltage
50°F (10°C)
40°F (4.4°C)
20 PSIG (1.4 bar)
-5%
100°F (38°C)
100°F (38°C)
80 PSIG (5.5 bar)
Remote Cond. Temps -20°F (-29°C) 120°F (49°C)
+10%
Maximum
Energy
Star
®