User`s manual

Prodigy Cuber System Information
Overall System Type:
Refrigeration: Mechanical, either air cooled, water cooled or remote cooled.
Water System: Inlet water solenoid valve fills reservoir once per cycle. Purge solenoid
valve opens to discharge some reservoir water once per cycle.
Control System: Electronic
Harvest cycle sensor: Conductivity probe
Water full/empty sensor: Conductivity probe
Bin Control: Curtain Switch
Ice type: Unified
Harvest system: Hot gas defrost with mechanical assist
Electrical Components:
Compressor
Contactor
Water Pump
Inlet Water Solenoid Valve
Purge or purge Valve
Fan Motor(s)
Fan motor pressure control
High pressure cut out – certain AC models only
Harvest Assist Solenoid(s)
Hot Gas Valve(s)
Controller
Transformer – 12v AC for the controller only
Water Level Sensor
Ice Thickness Sensor
Curtain Switch(es)
September 2006 Page 21