Use and Care
January 2015 Page 36
Air Cooled - Average heat load for air conditioning unit sizing
Model BTUH
C0322 5200
C0522 7900
C0330 5200
C0530 7900
C0630 12700
C0722 12700
C0830 13700
C1030 16200
C1448 20000
C1848 27400
Water Cooled Water Use - condenser only,
Model GPM, 45
o
F. water inlet temp GPM, 70
o
F. water nlet temp
C0322 .2 .3
C0522 .3 .7
C0330 .1 .3
C0530 .3 .5
C0630 .4 .7
C0803 .4 .8
C1030 .4 1.0
C1448 .6 1.1
C1848 1.0 1.8
C2148 1.0 2.0
Heat Load & Condenser Water GPM