SDS

Scotchgard Protector for Rugs & Carpet (Cat No 1023H) 02/18/16
__________________________________________________________________________________________
Page 5 of 11
8.2.1. Engineering controls
Provide appropriate local exhaust when product is heated. Do not remain in area where available oxygen may be reduced.
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure
Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment.
8.2.2. Personal protective equipment (PPE)
Eye/face protection
Select and use eye/face protection to prevent contact based on the results of an exposure assessment. The following eye/face
protection(s) are recommended:
Indirect Vented Goggles
Skin/hand protection
No chemical protective gloves are required.
Respiratory protection
Use a positive pressure supplied-air respirator if there is a potential for over exposure from an uncontrolled release, exposure
levels are not known, or under any other circumstances where air-purifying respirators may not provide adequate protection.
An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of
a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator
type(s) to reduce inhalation exposure:
Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates
Half facepiece or full facepiece supplied-air respirator
For questions about suitability for a specific application, consult with your respirator manufacturer.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
General Physical Form:
Liquid
Specific Physical Form:
Aerosol
Odor, Color, Grade:
Milky white liquid in aerosol.
Odor threshold
No Data Available
pH
>=9 [Details: (Liquid fill only)]
Melting point
Not Applicable
Boiling Point
No Data Available
Flash Point
No flash point
Evaporation rate
No Data Available
Flammability (solid, gas)
Not Applicable
Flammable Limits(LEL)
No Data Available
Flammable Limits(UEL)
No Data Available
Vapor Pressure
No Data Available
Vapor Density
No Data Available
Density
1.0 g/ml
Specific Gravity
Approximately 1 [Ref Std: WATER=1] [Details: (Liquid fill
only)]
Solubility In Water
Complete
Solubility- non-water
No Data Available
Partition coefficient: n-octanol/ water
No Data Available
Autoignition temperature
Not Applicable
Decomposition temperature
No Data Available
Viscosity
No Data Available