MSDS

MATERIAL SAFETY DATA SHEET Scotchgard Fabric & Upholstery Cleaner 06/21/10
_________________________________________________________________________________________________
Page 3 of 9
4.2 NOTE TO PHYSICIANS
Exposure may increase myocardial irritability. Do not administer sympathomimetic drugs unless absolutely necessary.
SECTION 5: FIRE FIGHTING MEASURES
5.1 FLAMMABLE PROPERTIES
Autoignition temperature
Not Applicable
Flash Point
Not Applicable
Flammable Limits - LEL
Not Applicable
Flammable Limits - UEL
Not Applicable
5.2 EXTINGUISHING MEDIA
Non-combustible. Choose material suitable for surrounding fire.
5.3 PROTECTION OF FIRE FIGHTERS
Special Fire Fighting Procedures: Exposure to extreme heat can give rise to thermal decomposition. Wear full protective
equipment (Bunker Gear) and a self-contained breathing apparatus (SCBA).
Unusual Fire and Explosion Hazards: Closed containers exposed to heat from fire may build pressure and explode. Aerosol
container contains gas under pressure. No unusual effects are anticipated during fire extinguishing operations. Avoid breathing the
products and substances that may result from the thermal decomposition of the product or the other substances in the fire zone. Keep
containers cool with water spray when exposed to fire to avoid rupture. Aerosol container contains flammable material under
pressure.
Note: See STABILITY AND REACTIVITY (SECTION 10) for hazardous combustion and thermal decomposition
information.
SECTION 6: ACCIDENTAL RELEASE MEASURES
Personal precautions
Observe precautions from other sections. Ventilate the area. WARNING ! A motor could be an ignition source and could cause
flammable gases or vapors in the spill area to burn or explode. If it can be done safely, place the leaking container in an exhaust hood
or well- ventilated area. Contain spilled material.
Environmental procedures
Dispose of collected material as soon as possible.
Clean-up methods
Contain spilled material. Clean up residue. Place depressurized can and clean up wastes in a closed container approved for
transportation by appropriate authorities.
In the event of a release of this material, the user should determine if the release qualifies as reportable according to
local, state, and federal regulations.