User manual
User Manual
Front Panel Operation
Page 3-6 (Rev. 2.0 /August 2005)
3.1.2.4. Edit Value Screen
The Edit Value screen enables setting up a parameter value. The parameter
value can be a number or a string of characters. Each digit or character is set up
individually.
In this example, the Edit Value screen displays the following information:
Pcr1
1062 [Hex]
<0000 – 1FFF>
A. Top line displays the parameter name (
Pcr1
). The pencil icon
indicates that the parameter value is editable.
B. Second line displays the current value of the parameter. Changing the
value of the parameter is performed using the arrow keys:
• [Left] and [Right] arrow keys are used to mark a digit or a character
for change. The marked digit or a character is displayed with white
character over black background (see example above)
• [Up] and [Down] arrow keys are used to scroll up or down the digits
(range 0 thru 9) or the characters (a to z, A to Z, 0 to 9 and ctr.). The
scroll range can be limited to prevent setting up values out of range.
C. Third line displays the allowed range of values for the parameter.
Press [ESC] to abort the setup and return one level up to the Edit Value
Screen without changing the parameters.
Press [Enter] to accept the value. The display returns one level up to the
Edit Value Screen and the new value is displayed as the current value of the
parameter.