Product guide

HOMELINK 55
SCANTRONIC (2 Year Warranty)
ADI-GARDINER operate the COOPER SECURITY LIMITED EXCHANGE SCHEME for a range of Scantronic products. All product will be under
warranty for 24 months as from date of purchase. Product faulty within this period will be replaced with brand new product. Product faulty
outside the 24 months will be charged for as previously.
09448EUR-90 (9448+ Style) 7 zone plastic control panel with on board keypad. 6 zones + EE + Global Tamper. Full or part set options.Accepts up
to two 09427EUR-80 remote keypads.Programmable part set option, zone attributes include PA, normal alarm, chimes,omit, not used, part set omit.
DAY system status LED, 10 event log,500mA auxiliary output. Communicator outputs.
09448EUR-95 (9448+ Style ES) 7 zone control panel. Plastic end station c/w 09427EUR-80 keypad.As above, connection for up to 4 of
09427EUR-80 keypads.
09427EUR-80 remote keypad for use with 09448EUR-90/95 and 09448UK-60.
09651UK-00, non-PD6662:2004 version, 8 zone control panel c/w 9930EN-00 LCD keypad. Metal end station,8 fully programmable zones (CC, 2 wire
with global tamper or 2 wire FSL), full and 3 part set options.Accepts up to four 9930EN-00 or 9940EN-00 LCD keypads and one 9928 keyswitch interface.
Accepts optional plug-on ScanProx proximity module.16 users codes (15 prox tags), 250 event log with time and date stamped.500mA auxiliary power
output. 8 wire-in secondary communications outputs.(Non DD243:2004 compliant).
09651EN-00, 8 zone control panel c/w 9930EN-00 LCD keypad.Metal end station,8 fully programmable zones (CC, 2 wire with global tamper
or 2 wire FSL), full and 3 part set options.Accepts up to four 9930EN-00 or 9940EN-00 LCD keypads and one 9928 keyswitch interface.Accepts optional
plug-on ScanProx proximity module. 50 users codes (49 prox tags),700 event log with time and date stamped. 500mA auxiliary power output.
8 wire-in secondary communications outputs. (Non DD243:2004 compliant).
09651EN-40 - 8 zone control panel c/w 9940EN keypad. Metal end station, 8 fully programmable zones (CC, 2 wire with global tamper or 2 wire FSL),
full and 3 part set options.Accepts up to four 9930EN-00 or 9940EN-00 LCD keypads and one 9928 keyswitch interface.50 users codes (49 prox tags),
700 event log with time and date stamped. 500mA auxiliary power output. 8 wire-in secondary communications outputs. (Non DD243:2004 compliant).
09751EN-00 8 - 24 zone control panel c/w 9930EN-00 LCD keypad. Metal end station with 8 fully programmable zones on board expandable to 24
(CC with GT or 2 wire FSL), choice of hardwire or narrow-band radio 868MHz ‘Class VI’ expansion. Built in multi format communicator and 300 baud V21
modem.Alarm reports can be fast format, contact ID or SIA 1,2 or 3.Full remote UDL, remote control, remote servicing and system diagnostics via PC based
‘Windows’ downloader program, 8 fully programmable secondary communications outputs,3 fully programmable transistorised panels outputs.Accepts up
to 4 of 9930EN-00 or 9940EN LCD keypads or keyswitch interface 09928EUR-00.Full (A) and 3 parts sets (B,C & D). Partition option, 50-4 digit user access
codes + installer and duress code (49 prox tags). 700 event timer and date stamped log, 1 amp PSU, 7.0Amp battery, conforms to PD6662:2004 Grade 2
Environmental Class ll,ACPO DD243 2002, PD6662:2004 Class 2 / BS6799 ‘Class VI’ for radio installations.
09751EN-40 - 8 - 24 zone control panel c/w 9940EN keypad. Metal end station with 8 fully programmable zones on board expandable to 24
(CC with GT or 2 wire FSL), choice of hardwire or narrow-band radio 868MHz ‘Class VI’ expansion. Built in multi format communicator and 300 baud V21
modem.Alarm reports can be fast format, contact ID or SIA 1,2 or 3.Full remote UDL, remote control, remote servicing and system diagnostics via PC based
‘Windows’ downloader program, 8 fully programmable secondary communications outputs,3 fully programmable transistorised panels outputs.Accepts up
to 4 of 9930EN-00 or 9940EN LCD keypads or keyswitch interface 09928EUR-00.Full (A) and 3 parts sets (B,C & D). Partition option, 50-4 digit user access
codes + installer and duress code (49 prox tags). 700 event timer and date stamped log, 1 amp PSU, 7.0Amp battery, conforms to PD6662:2004 Grade 2
Environmental Class ll,ACPO DD243 2002, PD6662:2004 Class 2 / BS6799 ‘Class VI’ for radio installations.
09752EN-00 8 - 32 zone control panel c/w new 9940EN LCD keypad.As 9751EN-00 plus expandable to 32 zones, 3 fully programmable outputs
(2 relays and 1 transistorised). Local downloading RS232 serial port.
09853EN-00 8 - 40 zone control panel c/w 9940EN LCD keypad. Metal end station with 16 onboard fully programmable zones expandable to 40 zones
(2 wire FSL). Choice of hardwire or 868MHz ‘Class VI’ Radio expansion. Built in multi format communicator and 2400/300 baud full duplex modem.Alarm
reports can be Fast Format, Contact ID or SIA 1 or 2 or 3. Full remote or local UDL,remote control,remote servicing and system diagnostics via PC based
‘Windows’ Downloader program. 16 fully programmable secondary communications outputs (plug-by and 8-channel Scantronic plug-on footprint), 4 fully
programmable panel outputs (2 relay & 2 transistorised). Local printer output, full RS232 serial port for local programming.Accepts up to 4 LCD keypads
(9940EN or 9930EN-00) or keyswitch interfaces.Full (A) and 3 part sets (B,C&D) or 4 partitions ABCD. 50 x 4 digit user access codes + installer and duress,
7000 event time & date stamped log. 1.3 Amp psu, 7.0/17Amp battery. Conforms to PD6662:2004 Grade 3 Environmental Class ll and PD6662:2004
Grade 2/BS6799 ‘Class VI’ for radio installations.
Homelink 55 24-zone hybrid control panel kit, c/w 9940EN LCD keypad with prox reader. Blank metal end station,16 zone radio expander and
8 wired programmable zones Built-in multi-format communicator & 300 baud V21 modem.Alarm reports can be fast format,contact ID (CID) or
SIA 1, 2, 3.Full remote UDL,remote control, remote servicing and system dynamics via PC-based ‘Windows’ downloader program. 8 fully programmable
secondary communications outputs, 3 fully programmable transistorised panel outputs.Accepts up to 4 9930EN,9940EN, 9941EN or 9943 LCD keypads
or any combination. Radio section compatible with most 700r series transmitters and detectors and 727/728rEUR-00 super encrypted, rolling code fobs.
CONTROL PANELS & ACCESSORIES (continued)
33
Control Panels