User`s manual

Schilling Marking Systems GmbH
In Grubenäcker 1 DE-78532 Tuttlingen
+49 (0)7461 9472-0 +49 (0)7461 9472-20
info@schilling-marking.de
www.schilling-marking.de
MK3 - User’s Manual 62
Maintenance
6.4 MEANING OF THE LED
TYPE MEANING NOTES
+35 MOTOR ELECTROVALVE POWER +35 Volt
+24 I/O AUXILIARY CIRCUIT POWER +24 Volt
+12 ELECTROVALVE SERVICE POWER +12 Volt
+5P MOTOR LOGIC POWER +5 Volt
+5L CONTROLLER POWER +5 Volt
EV ELECTROVALVE ON on for EV enabled
ST INPUT OF MARKING START on for START enabled
SP INPUT OF MARKING STOP on for STOP enabled
RD CONTROLLER OK on for Controller OK
FM MARKING END off during the marking
PU STYLUS COMMAND on for stylus enabled
MP PRESSURE MIN. on for min. pressure switch closed
IM MOTOR RESOLUTION 1 - ½ step
EN MOTOR ENABLE on for motors free
CX CLOCK MOTOR X on at each step of the motor movement X
CY CLOCK MOTOR Y on at each step of the motor movement Y
CZ CLOCK MOTOR C OR Z on at each step of the motor movement C or Z
! ATTENTION ! If in the SM-Program C- or Z-axis is akivated, the Y-axis is deactivated
DX DIRECTION MOTOR X off for motor to direction X zero mechanic
DY DIRECTION MOTOR Y on for motor to direction Y zero mechanic
DZ DIRECTION MOTOR C OR Z on for motor to direction C or Z zero mechanic
FX END TRAVEL AXIS X on for end travel X on zero mechanic
FY END TRAVEL AXIS Y on for end travel Y on zero mechanic
FZ END TRAVEL AXIS C OR Z on for end travel C or Z on zero mechanic