User`s manual
Schilling Marking Systems GmbH
In Grubenäcker 1 DE-78532 Tuttlingen
+49 (0)7461 9472-0 +49 (0)7461 9472-20
info@schilling-marking.de
www.schilling-marking.de
MK3 - User’s Manual 60
Maintenance
6. MAINTENANCE
6.1 Introduction
The inspection consist of standard maintenance that can be done directly by the user, and of
preventive and/or corrective interventions that can be carried out only by the Technical Service.
As all the electric and mechanic appliances, this unit needs not only a correct use but also the
maintenance and inspections at regular intervals. This care will grant a continuous and efficient
operation of the marking system.
6.2 Standard Maintenance
This maintenance must be carried out periodically every 6 months assuming an use of 8 hours
per day of the stamper.
Lubricating the movements bars
Remove the protection carter.
Remove the dust in the interior of the equipment.
Dampen a not abrasive cloth with vaseline oil (type for sewing-machine) and clean
accurately the shafts.
Pneumatic Group
Dismount the air filter.
Blow in by means of an air gun (max 6 atm.) in opposite direction of the normal
operation.
Verifying and adjusting the belt tension
Apply a load of 150 gr. on the middle point of the belts between the pulleys and verify
that the flexion is less of 5 mm.
If not, adjust on both tensioning pulleys.
Electrovalve
Verify that the electrovalve silencer is not obstructed by dust.
To access , unscrew the silencer and blow in by means of an air gun (max 6 atm.) in
opposite direction of the discharge.