MK3 - User’s Manual 24
Unpacking and installation
2.6 Switching on the system
2.6.1 General
Before to switch on the system, verify that:
1. all the connections should be carried out correctly,
2. ground bolts on the Controller and Marking head should be ground connected,
3. the 230/115 V arrangement on the Controller should be set according to the voltage
available,
4. the stylus should be correctly mounted,
5. the pneumatic circuit should be operating and the manometer read a pressure value not
more of 6 Bar.
Switch on the equipment by mean the power switch on the Controller. The system will be
automatically powered and the stylus moved on the rest position (left up of the working area).
Now use the application program to carry out the marking cycles.
2.6.2 Switching on with default data loading and job reset
When firmware upgrade must be performed, it is necessary to load the default data into the
controller memory with the following procedure:
- switch off the equipment,
- pushing on both the
START and STOP buttons of the remote I/O switch on the Controller;
wait for about 3 seconds before to release the buttons.
With this operation the default data and the job reset will be perfoprmed.
To perform only the job reset operation, switch on the equipment pushing on the
STOP button of the remote I/O device for 5 seconds.