User`s manual
Schilling Marking Systems GmbH
In Grubenäcker 1 DE-78532 Tuttlingen
+49 (0)7461 9472-0 +49 (0)7461 9472-20
info@schilling-marking.de
www.schilling-marking.de
MK3 - User’s Manual 21
Unpacking and installation
Serial cable Controller-PC
Connect the serial port COM1 or COM2 of the PC to the RS232 connector of the Control Unit
with a cable of 15 m max. On the Control Unit the connector is 9 pins/female type.
If the COM1/2 of the PC is equipped with a 9 pin connector, make the connections in the figure.
If the COM1/2 of the PC is equipped with 25 pin connector, use an adapeter 25 pin/9 pin or end
the PC side cable on 25 pin connector making the connections in the figure.
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
2
3
4
5
7
8
13
14
25
6
20
Controller
PC
Controller
PC
9 pin male 9 pin female
9 pin male
25 pin female
RXD
TXD
GND
RXD
TXD
RXD
TXD
GND
Warning The cable screen must be soldered to only one of the two connectors (side PC