User manual
56
1. Remove the anti-freezing cover. The anti-
freezing caps are mounted inside.
2
. Make sure that the anti-freezing caps are
internally free of water.
3
. If they contain water, the unit must be
inspected and, if necessary, serviced by a
service technician approved by Interspiro.
4
. Check that the anti-freezing caps have not been damaged. If damage is detected or suspected, the
anti-freezing caps must be replaced. Make sure that the anti-freezing caps are not deformed when
installing them in the base.
5
. Replace the anti-freezing caps in the anti-freezing cover.
6. Replace the anti-freezing cover in the regulator unit.
12.3.6 CONTROLLING THE VISOR
Inspect the visor of the full-face mask and look for cracks in the plastic. If there are cracks in the visor, it
must be replaced by a service technician approved by Interspiro.
12.3.7 CHECKING RUBBER AND PLASTIC PARTS
Inspect the rubber parts of the full-face mask by stretching and bending them.
Check the connection points around the buckles and metal bands. Check all plastic parts (sealing surfaces,
bayonet couplings, xing cover and screws) If there are cracks or other damage, the part in question must