User manual
41
8 FILLING
8.1 FILLING INTERSPIRO FULLY COMPOSITE CYLINDERS
The following measures must be performed when filling Divator Lite cylinders with an initial pressure
less than 30 bar (435 psi).
• The filling rate must be limited to no more than 30 bar (435 psi) a minute. Using an Interspiro Fill-
ing Adapter is recommended.
• The cylinder pack must always be filled in an upright position with the valves pointing upwards.
• When filling cylinders or cylinder packs having an initial pressure exceeding 30 bar (435 psi), a
normal filling rate can be used.
• As a minimum, the air with which the cylinders are filled should comply with the requirements in
European standard EN 12021 or the purity Standard for US FED SPEC BB-A-1034 Grade A.
8.2 FILLING ADAPTER
The filling adapter (item no. 99369-01) connects the cylinder valve to the filling hose.
The adapter is designed for filling Divator Lite cylinder packs 323.4 and 326.7.
The adapter has a built-in nozzle that limits the filling rate to approximately 30 bar (435 psi) a
minute.