User manual

41
8 FILLING
8.1 FILLING INTERSPIRO FULLY COMPOSITE CYLINDERS
The following measures must be performed when filling Divator Lite cylinders with an initial pressure
less than 30 bar (435 psi).
The filling rate must be limited to no more than 30 bar (435 psi) a minute. Using an Interspiro Fill-
ing Adapter is recommended.
The cylinder pack must always be filled in an upright position with the valves pointing upwards.
When lling cylinders or cylinder packs having an initial pressure exceeding 30 bar (435 psi), a
normal filling rate can be used.
As a minimum, the air with which the cylinders are filled should comply with the requirements in
European standard EN 12021 or the purity Standard for US FED SPEC BB-A-1034 Grade A.
8.2 FILLING ADAPTER
The filling adapter (item no. 99369-01) connects the cylinder valve to the filling hose.
The adapter is designed for filling Divator Lite cylinder packs 323.4 and 326.7.
The adapter has a built-in nozzle that limits the filling rate to approximately 30 bar (435 psi) a
minute.