Pre-terminated coaxial feeders are available for 5, 10 or 15 metre requirements. High frequencies can equate
to high power losses. Always use the best quality cable. RG58 is only acceptable on cable runs of up to 5
meters. We recommend RG213 or equivalent on greater lengths. If in doubt consult your dealer. Coaxial cable
intended for TV satellite or CCTV installations is normally 75 ohm and therefore totally unsuitable and can cause
severe transmitter damage.
Program Parameters
The standard models are factory pre-set and should not under any circumstances be adjusted by the customer.
The factory settings can be viewed for the purposes of verification when ordering additional components etc.
The system parameters are protected from accidental change by password control. To enter the system type:
( 72765 then press ENTER
*USER OPTIONS*
1: Setup 2: Range
1: Setup
Press key 1. The screen changes to:
PAGER BAUD RATE
1:1200 5: 512
To change the transmission baud rate enter 1 for 1200 or 5 for 512
After pressing your selection the screen will change to:
*BASE IDENTITY*
> 0100000
The displayed Base number can be used or you can type in the required number.
After pressing ENTER, the screen will change to confirm the new settings and you are prompted to accept by
pressing ENTER or Cancel. CANCEL will take you back to the *USER OPTIONS * screen.
After pressing ENTER, the screen display will return to the *USER OPTIONS* but with updated settings.
*USER OPTIONS*
1:SETUP 2:RANGE
Press key 2 to select the out of range option
Press any key to toggle between out of range OFF or out of range ACTIVE, then press Enter to confirm.
To return to the pager entry screen press ENTER or CANCEL when at the main programming menu.
The default setting for the out of range cap code is THE BASE ID, the beep type is A, the TX baud rate is 1200
NOTE! This feature is only available using 1200 baud.