2008 SCION xB AIR INLET INSTALLATION
Procedure
Issue A: 04/28/08 Page 36 of 48
(t) Install the TRD air cleaner outlet assembly.
(1) Install from the bottom of the car.
(2) Route the wire harness so it does not get
pinched between the vehicle frame and the
outlet assembly. (Fig. 18-16)
(
u) Install air cleaner outlet assembly with the
bracket under the battery carrier. (Fig 18-17)
(v) Secure the supplied TRD battery carrier to the
sub-frame using the four 12mm factory bolts.
(Fig 18-17). Torque bolts to 14 in-lb.
(w) Install chassis electrical ground using OE 10mm
bolt. Torque bolt to 48 in-lb.
(x) Install the TRD rubber inlet tube onto the TRD
air cleaner outlet using the supplied hose clamp.
(Fig 18-18)
(
1) Clock inlet tube so there is clearance to the
fuse box cover and also the wire loom
located on the back side of the headlamp.
(Fig. 18-18)
(2) Torque clamps to 12 in-lb.