Digital 7’’ Square (Hotplate) Magnetic Stirrer User Manual MS7-Pro Digital 7”Square Plate Magnetic Stirrer MS7-H550-Pro Digital 7”Square Hotplate Magnetic Stirrer Please read the User Manual carefully before use, and follow all operating and safety instructions! www.scilogex.
12.Associated Standards and Regulations ……………… 13 13.Technical Data ……………………………………… 13 14.Ordering Information ………………………………… 15 15.Main Spare Parts …………………………………… 16 15.1 Spare Parts Diagram …………………………… 16 15.2 List of Spare Parts ……………………………… 17 Contents Preface…………………………………………………… 2 Service…………………………………………………… 2 Warranty ………………………………………………… 2 1.Safety Instructions …………………………………… 3 2.Proper use……………………………………………… 4 3.Inspection ……………………………………………… 5 3.1 Receiving Inspection …………………………… 5 3.
Digital 7” Square(Hotplate)Magnetic Stirrer Welcome to the“Digital 7”Square (Hotplate) Magnetic Stirrer User Manual ”. Users should read this Manual carefully, follow the instructions and procedures, and be aware of all the cautions when using this instrument. Please provide the customer care representative with the following information: • Serial number on the rear panel • Description of problem (i.e.
Digital 7” Square(Hotplate)Magnetic Stirrer • Gradually increase the speed, reduce the speed if : - Stirring bar breaks away due to high speed - The instrument is not running smoothly, or container 1.Safety Instructions Warning! • Read the operating instructions carefully before use. • Ensure that only trained staff works with the instrument. • • Risk of burn! • Caution when touch the housing parts and the hotplate which can reach temperature of 550℃.
Digital 7” Square(Hotplate)Magnetic Stirrer • The tip of the measuring sensor must be at least 5 mm • • • • • 2.Proper use from vessel bottom; a distance of 10 mm is ideal. The instrument can only be disconnected from the main power supply by pulling out the main or the connector plug. The voltage stated on the label must correspond to the main power supply. Ensure that the main power supply cable does not touch the hotplate. Do not cover the device. The instrument may only be opened by experts.
Digital 7” Square(Hotplate)Magnetic Stirrer 3.Inspection 4.Control and Display 3.1 Receiving Inspection 4.1 Control elements Unpack the equipment carefully and check for any damages which may have arisen during transport. Please contact manufacturer/supplier for technical support. LED Heat (Hotplate model) Note: If there is any apparent damage to the system, please do not plug it into the power line. LCD Temperature Control Knob (Hotplate model) 3.
Digital 7” Square(Hotplate)Magnetic Stirrer Items 4.2 Display Descriptions Set the rated rotary speed. The Speed control Knob Stir stirring function is switched ON or OFF by pushing the knob. Temperature control knob Heat (Hotplate) Set the rated temperature. The heating function is switched ON or OFF by pushing the knob. LCD LCD displays the real working state and all settings.
Digital 7” Square(Hotplate)Magnetic Stirrer Remote Err 5.Trial run Display in case of remote control. • Make sure the required operating voltage and power supply voltage match. Display in case of error happening. • Ensure the socket must be properly grounded. • Ensure the power is off. • Plug in the power cable,ensure the power is on and begin Rated value/Real Display value in case of heating or value stirring function switching ON. initializing. Add the medium into the vessel with a stirring bar.
Digital 7” Square(Hotplate)Magnetic Stirrer 6.Initialization 7.Function: Heating 6.1 Initializing sequence The device is controlled by digital temperature control technology, which has two separate safe circuits. The hotplate is kept at a constant temperature by a digital control circuit. The hotplate temperature can also be monitored from a separate, adjustable safe circuit. The two temperature sensors (PT1000) internal for temperature control are built into the hotplate.
Digital 7” Square(Hotplate)Magnetic Stirrer case, set the heating temperature display the actual temperature may have the following differences:. - Hotplate center and outer edge. - The sample container and the container. In order to ensure the accuracy of the temperature inside the container, please use the external temperature sensor PT1000. Manufacture’s standard accessory. If the sensor is not plugged in,“Probe”will flash.
Digital 7” Square(Hotplate)Magnetic Stirrer 8.Function: Stirring The function“stirring”is switched on or off via rotating stirring knob. The speed is set on the knob (100 to 1500 rpm in steps of 10 rpm ). When both of function heating and stirring are switched on and those above operations are done, the LCD will shift to the speed value and come back to the temperature value in about 5 seconds. Figure 6 7.
Digital 7” Square(Hotplate)Magnetic Stirrer - Check whether the fuse is broken or loose • Fault in power on self test - Switch OFF the unit, then switch ON and reset the The unit can be controlled from an external PC (using the dedicated software) via the RS232 C serial interface fitted to the unit. Data communication from laboratory instrument to computer is only possible on demand of the computer.
Digital 7” Square(Hotplate)Magnetic Stirrer 11.Maintenance and Cleaning • Proper maintenance can keep instruments working • • • • properly and lengthen its lifetime. Do not spray cleanser into the instrument when cleaning. Unplug the power line when cleaning. Only use recommended cleansers: Dyes Isopropyl alcohol Warning! Cut off power when maintenance and cleaning.
Digital 7” Square(Hotplate)Magnetic Stirrer 12.Associated standards and regulations 13.Technical data Construction in accordance with the following safety standards: EN 61010-1 UL 3101-1 CAN/CSA C22.2(1010-1) EN 61010-2-10 Construction in accordance with the following EMC standards: EN 61326-1 Associated EU guidelines: EMC-guidelines: 89/336/EWG Instrument guidelines: 73/023/EWG * The above standards will be available from July 2011.
Digital 7” Square(Hotplate)Magnetic Stirrer Dimensions of heating (mm) 176×176 Weight [kg] 5.3 Heating power[W] 1000(hotplate model) Permitted ambient temperature[℃] 5-40 Temperature range [℃] RT-550 (hotplate model) Permitted relative humidity 80% Protection class acc. to DIN 60529 IP21 Temperature display[℃] LCD(hotplate model) RS232 interface Yes Temperature display accuracy [℃] 0.
Digital 7” Square(Hotplate)Magnetic Stirrer 14.Ordering information Cat No.
Digital 7” Square(Hotplate)Magnetic Stirrer 18900005 MS135.5 Black quarter pie, 4 holes,40 ml reaction vessel, Ø28mm, 43mm depth 18900048 MS135.6 Green quarter pie, 6 holes, 8ml reaction vessel, Ø17.75mm, 26mm depth 18900049 MS135.7 Golden quarter pie, 4 holesØ16ml reaction vessel, Ø21.6mm, 31.7mm depth 18100319 9-Pin interface line, suitable for StirPC-V2 software. 15.Main spare parts 15.1 Spare parts diagram Table 6 Note:The software StirPC-V2 can be freely downloaded from our website www.
Digital 7” Square(Hotplate)Magnetic Stirrer 15.
SCILOGEX, LLC 500 Four Rod Road Suite 122 Berlin, CT 06037 USA Tel:1- (860) 828-5614 Fax:1- (860) 828-5389 E-mail: info@scilogex.com Website:Http://www.scilogex.