MS-H(M)-S10 10-Channel Analog Hotplate Magnetic Stirrer User Manual MS-H-S10 10-Channel Analog Hotplate Magnetic Stirrer MS-M-S10 10-Channel Analog Hotplate Magnetic Stirrer Please read the User Manual and the related Video of this instrument on our website carefully before use, and follow all operating and safety instructions! The website www.scilogex.com Cat No.
Contents Contents Preface Service Warranty 1 Safety Instructions 2 Propervse 3 Inspection 3.1 Receiving Inspection 3.
MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer Preface • Description of problem (i.e., hardware or software) • Methods and procedures adopted to resolve the problems • Your contact information Welcome to the “10-Channel Analog Hotplate Magnetic Stirrer User Manual”. Users should read this Manual carefully, follow the instructions and procedures, and beware of all the cautions when using this instrument. Warranty You have purchased a scilogex instrument.
MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer 1 Safety Instructions clean, non-slip, dry and fireproof surface, do not operate the instrument in explosive atmospheres, with hazardous substances or under water. • Gradually increase the speed. Reduce the speed if : - The stirring bar breakaway because of too high speed - The instrument is not running smoothly, or container moves on the base plate. • Temperature must always be set to at least 25 ℃ lower than the burning point of the media used.
MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer • Ensure that the mains power supply cable does not touch the heating base plate. Do not cover the device. • The instrument may only be opened by trained experts • Keep away from high magnetic field. • Observe the minimum distances between the devices, between the device and the wall and above the assembly (min. 100 mm). mentioned in Chapter 1. 3 Inspection 3.
MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer 4 Trial run 5 Control elements Power LED • Make sure the required operating voltage and power supply voltage match. • Ensure the socket must be earthed. • Ensure the power be off and the speed control knob and the temperature control knob at the lowest position • Plug in the power cable,ensure the power be ON(Figure 3) • Add the medium into the vessel with a stirring bar. • Put the vessel above spots on the plate.
MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer LED Power Mains switch 6 Operation • The stirring function will continue to operate at the speed set point before the fault took place. • The heating function will continue to operate at the set point before the fault took place. • If the problem is not solved, please contact the technical service center. When the device is switched ON, the LED power is lit. Switch ON or OFF.
MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer 10 Technical data • Before using other method for cleaning or decontamination, the user must contact the manufacturer ascertain that this method does not destroy the instrument. • The instrument must be cleaned and put it into the initial packaging carton before sending to service for repair, avoiding the contamination of hazardous. • Use the instrument in a dry clean room and temperature stable environment.
MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer Material of plate Dimension of plate [mm] Dimensions (W×D×H) [mm] Weight [kg] Permitted ambient temperature[℃] Permitted relative humidity Protection class acc. to DIN 60529 Table 4 Silicone Films 180×450 182×552×65 3.2 811321049999 811321089999 5-40 80% 811311019999 IP42 811311029999 11 Products and Accessories Cat.No.
MS-H(M)-S10 10-Channel Analog (Hotplate) Magnetic Stirrer 18900008 18900009 12500005 18900011 18900015 Stirring bars(20mm x 8mm),1pcs/pk Stirring bars(25mm x 8mm),1pcs/pk Stirring bars(30mm x 6mm),1pcs/pk Stirring bars(40mm x 8mm),1pcs/pk Stirring bar mover,1pc Table 5