II. DC1000 Treadmill Power Requirements
The DC 1000 Treadmill is a high performance machine with certain power
requirements that must be maintained in the field for proper operation.
Inadequate power to the DC 1000 may result in intermittent failure of the
elevation system and improper speed valuation of the running belt.
The following electrical parameters must be met when determining existing
power in a facility:
1. Source voltage is between 108-132 volts on a dedicated 15 amp
circuit.
2. “Dedicated circuits” for each treadmill must be installed in
accordance with current voltage drop standards set by NEC code.
Note: A dedicated circuit is a power outlet reserved for the
exclusive use of one (1) and only one (1) treadmill. This
includes hot, neutral, and ground wires. This is done to
provide proper frame ground drainage of the treadmill. The
outlet should not be shared with any other piece of
equipment.
3. Have a proper outlet installed by a qualified electrician. See plug
diagram below.
Note: DANGER - Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician if you are in doubt as to whether the
product is properly grounded.
Grounded Outlet Diagram