V. Electrical Troubleshooting
A. Electrical Troubleshooting Table
Problem Possible Reasons Solutions
Unit keeps blowing fuses on
lower PCB.
Incoming voltage from the
wall to the treadmill is too
high.
Relays sticking on lower
PCB.
Defective lower PCB.
Verify voltage from the wall
to the unit.
Replace lower PCB. (Page
60-61)
Replace lower PCB. (Page
60-61)
Unit keeps blowing fuses in the
terminal block.
Relay sticking on lower
PCB.
Faulty limit switch.
Elevation motor binding.
Replace lower PCB. (Page
60-61)
Replace limit switch.
(Pages 53-55)
Replace elevation motor.
(Pages 50-52)
No lights on upper display.
Magnet not in place.
Power switch not in the on
position.
No power from wall outlet.
Blown fuse on lower PCB.
Bad Telco connection.
Faulty lower PCB.
Faulty upper PCB.
See flowchart. (Page 15)
See flowchart. (Page 15)
See flowchart. (Page 15)
Replace fuse.
Fix connection or replace
Telcos.
See flowchart. (Page 15)
See flowchart. (Page 15)
Upper display lights are dim.
Improper wall voltage.
Faulty power supply.
Damaged Telcos.
Check wall voltage.
Replace lower PCB. (Page
60-61)
Replace if needed.