User's Manual

E. Operation and Display
To save battery power, the sensor sends reading automatically only
when the temperature/humidity change is over 1/3%. If there is no any
change for a long time, the sensor will send the reading hourly to refresh the
display.
If there is any new reading transmitted from the sensor, the Base Unit will keep
the last reading on the display alternatively with the time display each for 5
seconds. You can clear the reading by Hot Key C.
Alarm Device: The system issues alarm when the reading is over the limits and
issues restore signal when the reading returns to the limits.
(High Limit)+1: High Limit Alarm
(High Limit)
(Low Limit)
(High Limit)-1: Alarm Restore
(Low Limit)+1: Alarm Restore
(Low Limit)-1: Low Limit Alarm
Control Device: The reading from this device will not issue any alarm even
over the limits.
Depends on the setting of High/Low limit operation, it can
control the operation of the switches or the Relay output.
High Limit Operation: Turn on at high limit reading and turn off at
low limit reading, to control all kinds of freezer or
dehydrator.
Low Limit Operation: Turn on at low limit reading and turn off at high
limit reading, to control all kinds of heater or humidifier.
High Limit Operation Device
(SW/Relay ON)
Low Limit Operation Device
(SW/Relay OFF)
(High Limit)
(Low Limit)
(SW/Relay OFF)
High Limit Operation Device
(SW/Relay ON)
Low Limit Operation Device
(
Low Limit
)
-1
(High Limit)+1