User's Manual
STATUS INDICATORS
There are three LED indicators in green, yellow and red colors on the front panel. They represent the system
operation mode and alarm/ warning status as listed in the following table.
Note: If there is any pending alarm message in the event log memory, the ALARM indicator (red LED)
will be lighted and a warning “Dong” sound will be issued in every 5 minutes to alert the user
when the system is in Disarm Mode (Refer to (4-3) Set Sound-Alarm Warning). The indicator
(red LED) and the warning sound will be turned off after the user runs the Event Check function
(Refer to (2) System Check-Event Check) or press (Hotkey) to clear the status indicator
in Disarm Mode.
Sensors & Zones (All sensors are divided into five main categories)
1. 32 Controller /Panic Devices (C): Remote Controller, Keypad, Card Reader.
2. 128 Burglary Sensors/Sirens (B): Door Magnet, PIR (Passive Infrared), Glass Break Detector,
Vibration Sensor, Pressure Change Detector, Wireless Siren.
3. 64 Fire Sensors (F): Smoke/Heat/Flame Detector, CO Detector, Gas Detector, Fire Call Point.
4. 32 Medical Help Transmitters (M): Medical Button, Inactivity Detector.
5. 32 Special Sensors (S): Temperature/Humidity Sensor, Flood,/Light Detector, Analog/Power Meter.
All the sensors are numbered with two double-digit zone numbers from (01-01) to (99-99), the first
two-digit number is the Group number and the second two-digit number is the Unit number, set by
the Installer in the initial installation.
Ex.1, C 01-02: Controller number 01-02 (Group number 01, Unit number 02).
Ex.2, B 02-04: Burglar Sensor number 02-04 (Group number 02, Unit number 04).
Group number: The user can group several sensors by using the same Group Number. For
example, the sensors in the first floor can be assigned as group number “01” and the sensors in
the second floor can be assigned as group number “02”.
Note: Special group numbers
”00” for Base Unit (Z), “80” to “89” for Xkeypad (C) , “90” for status indicator (Special Sensor).
“91” to “99” for the Partial Arm Zones (Z) (Please refer to APPENDIX A-8).
State LED Red Yellow
Green
DISARM OFF OFF Flash
HOME OFF Flash OFF
AWAY Flash OFF OFF
DISARM with Warning Message OFF ON Flash
DISARM with Alarm Message ON OFF Flash
DISARM with Warning & Alarm
Message
ON ON Flash
HOME with Warning Message OFF ON OFF
HOME with Alarm Message ON Flash OFF
HOME or AWAY with Warning
& Alarm Message
ON ON OFF
AWAY with Warning Message Flash ON OFF
AWAY with Alarm Message ON OFF OFF
4
ALARM WARM