User's Manual

SPECIFICATIONS
Base Unit
Input Power: 15VDC/800mA regulated.
Standby Current: 50mA.
RF : (Follows local regulations, other frequencies as requested)
Frequency: 915Mhz receiver, 433Mhz transmitter
Data Modulation: OOK.
Power: less than 10mW.
Range: about 100m to 300m @open field, 25 (Depends on sensors).
Receiver Type: super heterodyne.
RF Security Code: 16,777,216 combinations with check sum for each type of sensors.
More than 4 billion combinations in total.
Communication Link: Standard PSTN (land line), Optional Ethernet
Telephone Dialing: Pulse/Tone selectable.
Preset Telephone Number: 10 phone numbers, one pager, 2 CMS data links
Voice Recording: 120 seconds in total.
Emergency announcement in 6 segments, 13 seconds for common segment, 4 seconds
each for Panic, Burglar, Fire, Medical, Special and Latchkey/ Power segments.
Event Log: max. 512 records.
Display: 3 LEDs, 2x16 LCD panel with blue color backlight.
Sensor Zones: total 288 zones. (Burglar zones x 128, Fire zones x 64, Controller zones x 32,
Medical zones x 32, Special sensor zones x 32)
Memory Back-up Time: Min. 3 months after power break.
Battery Back Up Operation Time: about 15-26 hours standby. (depends on back up battery type, only for the
operation of the Base Unit)
Password: 14 passwords each with max. 8 digits.
3 Wire Sensor Inputs: Each can be assigned as Panic, Burglar, Fire, Medical, Tamper or Controller.
Alarm Out: 230V AC /5A rate relay contacts or DC output selectable.
Delay Activation Time: 0- 255 seconds programmable.
Digital Interfaces COM1(RJ9): UART (0-5V, 9600/ 8 bits/no parity/1stop bit)
For RS-232 Adaptor, USB Adaptor or Ethernet Adaptor..
Digital Interface COM2(RJ45): (for switch control interface)
Switch control: Control of 16 units X-10 switches or (XRM-01) Relay Modules. I2C Adaptor
(optional)
Remote Display Memory: 30 characters/set, total 10 sets.
Internal Siren: 110dB at 30cm distance.
CMS protocol: Contact ID with
Clock Accuracy: within 5 seconds daily.
Telephone Line Cut Detection Voltage: 20V+/- 4V. (this function may not be used in some countries.)
Operation Temp.: -10~50.
Storage Temp.: -20~60.
Humidity: 10-95%RH.
Size: 248x180x52 mm.
Weight: about 950 g.
Note: External GSM is an option for European market, LS-30 dont use wi-fi, only wire Ethernet interface.
(The manufacturer reserves the right to change the specifications without prior notice)
34