User's Manual
(5) CMS Mode Set CMS1
Set Mode Change Report Report On/ Off
Set CMS2
Auto Link Check Auto Link Check On Check Interval
Loopbcak Test Auto Link Check Off
Set 2 Way Audio 2 Way Audio ON/OFF
Set DTMF Data Time DTMF Data=50ms /100ms
Set Telephone Number Telephone Number
Account Number
Set Password CMSx Number
(CMS1 only)
Set CMS Report Report All/ One
Ethernet Report (CMS1 only)
Mode Change Report: ON /OFF (default=OFF, For PSTN)
Mode Change Report On: The LS-30 will report to the CMS if the operation mode
(Away/Home/Disarm) has been changed.
Auto Link Check: ON/OFF (default=OFF, For PSTN)
Auto Link Check On: The LS-30 will send a check signal to the CMS periodically.
Loopback Test: (For PSTN) The LS-30 will send a link check signal to the CMS immediately.
2 Way Audio: ON/OFF (default=OFF, For PSTN)
2 Way Audio ON: The Base Unit will enter into 2-way voice communication mode after sending the
alarm report to the CMS.
(This function only works with a digital receiver using Contact ID and has 2-way voice capability.)
DTMF Data Time: 50ms/100ms for PSTN report (default=50ms, For PSTN)
Select the DTMF data pulse time as 50ms or 100ms for the Contact ID protocol.
(Please consult with your CMS provider if you want to change this parameter.)
Telephone number & account number:
*The PSTN (land line) CMS telephone number (16 digits Max.).
*The user account (8 digits Max.). The CMS1 account number is also used for IP Alarm Report
Password: The CMS password to access the LS-30 Base Unit.
CMS Report: (default, Report ALL)
Report All: Report to CMS1, CMS2 and Internet service centers.
Report One: Stop further CMS report if any one of the above reports is successful.
Ethernet Report: YES/NO (default NO), only for the system equipped with Ethernet/wifi/GPRS Adaptor.
Alarm message will be reported to the CMS server through the Internet.
33